What Is
Included
To Begin
Product
Description
Product Overview
AC Power

Power Linking

Fuse Replacement

• MegaStrobe™ FX12
• Power Cord
Unpack your MegaStrobe™ FX12 and make sure you have received all
parts in good condition. If the box or contents appear damaged, notify the
carrier immediately, not CHAUVET®.
The MegaStrobe™ FX12 is a high-powered LED strobe light. Lightweight,
robust housing permits easy transport and advanced software controls
dimming, strobe rate, chases, and operating modes without a controller.
Power Out
Power In
Back Panel View
This product has an auto-ranging power supply that can work with an input
voltage range of 100~240 VAC, 50/60 Hz.
You can link up to 26 MegaStrobe™ FX12 products at 120 VAC and 48
units at 230 VAC.
1. Disconnect the product from power.
2. Using a flat-head screwdriver, loosen the fuse holder and pull straight out.
3. Remove the blown fuse from the holder and replace with a fuse of the exact
same type and rating.
4. Re-insert the fuse holder and reconnect power.