Table 1. Features and specifications
Microprocessor(s): Supports up to
two Intel Xeon dual-core, quad-core,
or hex-core microprocessors. For the
specific type and speed information
about the microprocessor, use
the Setup Utility program. See
"Using the Setup Utility program" on
page 103. For a list of the supported
microprocessors for your server, go to
http://www.lenovo.com/thinkserver.
On the ThinkServer systems page,
click Products ➙ Options ➙
ThinkServer Processors.
Memory modules:
• Minimum system memory: 2 GB
• Maximum system memory: 64 GB
(eight memory slots, each with one
8 GB RDIMM installed)
• Types: ECC, 1333 MHz, DDR3
registered SDRAM DIMMs only
• Slots: Eight dual inline memory
module (DIMM) slots
• Supports 2 GB, 4 GB, and 8 GB
RDIMMs
Integrated graphics card:
• 8 MB video memory
Size:
• Height: 43.6 mm (1.72 inches)
• Width: 436 mm (17.17 inches)
• Depth: 568 mm (22.36 inches)
• Maximum weight: 17 kg (37.48 lb)
when fully configured
8
ThinkServer RD230 Hardware Maintenance Manual
Optical drive:
• Slim DVD/RW
Hard disk drive expansion bays
(depending on the model):
Up to four 3.5-inch SATA or SAS hard
disk drives
Expansion slots:
• Three PCI Express slots on the
system board and the PCI Express
x16 slot is for a riser card (there is
one PCI Express x16 slot on the
riser card)
Power supply: Single 600-watt
power supply
System fans: Five system fans
with automatic energy-saving noise
reduction technology
Integrated functions:
• Two single-port Gb Ethernet
controllers
• Six USB 2.0 connectors (two front
and four rear)
• Two RJ-45 Ethernet connectors
• One serial port
• One Video Graphics Array (VGA)
monitor connector
Environment:
• Air temperature:
– Server on: 10°C to 35°C (50°F
to 95°F); altitude: 0 to 914.4 m
(3 000 ft)
– Server on: 10°C to 32°C (50°F
to 89.6°F); altitude: 914.4 m (3
000 ft) to 2 133.6 m (7 000 ft)
– Server off: 10°C to 43°C (50°F
to 109.4°F); maximum altitude:
2 133.6 m (7 000 ft)
– Shipping: -40°C to 60°C (-104°F
to 140°F)
• Humidity:
– Server on: 8-90%,
non-condensing
– Server off: 8-90%,
non-condensing
– Shipping and storage: up to
93%, non-condensing
• Particulate contamination:
Attention: Airborne particulates
and reactive gases acting alone
or in combination with other
environmental factors such as
humidity or temperature might
pose a risk to the server.

Advertisement