Replacing The Cover - IBM System x3250 M3 Type 4251 Installation And User Manual

1u-high rack model server
Hide thumbs Also See for System x3250 M3 Type 4251:
Table of Contents

Advertisement

2. Turn off the server and peripheral devices and disconnect the power cords and
3. Align the DIMM air baffle over the DIMMs so that the baffle pin on the left side

Replacing the cover

To replace the server cover, complete the following steps:
1. Align the cover over the server (toward the rear of the server) until the cover
2. Slide the cover forward toward the front of the server until the cover is
54
IBM System x3250 M3 Types 4251, 4252, and 4261: Installation and User's Guide
all external cables (see "Turning off the server" on page 16).
of the air baffle aligns with the pin hole next to fan 2 and the baffle pin on the
right side of the air baffle aligns with the pin hole next to fan 5 on the system
board, and lower it into the server.
edges slip into position over the chassis.
Important: Before sliding the cover forward, make sure that all the tabs on both
the front, rear, and side of the cover engage the chassis correctly. If all the tabs
do not engage the chassis correctly, it will be hard to remove the cover later.
completely closed.
Air baffle