Part 2 Functions & Controls
4.3 Air volume control
• UIndoor fan motor control have 6 steps or 8 steps.
• UAir volume is controlled "SH", "H", "MH", "M", "ML", "L" by the
remote controller.
• "SL" step is selected in "Sleep Mode" operation.
4.4 Natural Air Control(Natural Wind)
• When the Auto Step is selected and then operated, the high, medi-
um, or low speed of the airflow mode is operated for 2~15 sec. ran-
domly by the Chaos Simulation.
4.5 Auto Swing
• By the Auto swing key input, the horizontal vane automatically operates with the Auto swing or it is fixed to the desired
direction.
4.6 Sleep mode Auto control
• When the set sleep time is reached set time of [1,2,3,4,5,6,7hour] input by the remote control during the operation, the
operation of the appliance stops.
• When the appliance is on pause, the sleep timer mode cannot be input.
4.6.1 Sleep timer operation for cooling cycle
• While in cooling mode , 30 min. after the start of the sleep timer, the setting temperature increases by 1° C(2° F).
After another 30minutes lapse, it increases again by 1°C(2° F).
Setting temp. (˚C)
Cooling ON temp.
(Setting temp. +0.5˚C(+1˚F))
Cooling OFF temp.
(Setting temp. -0.5˚C(-1˚F))
NOTE: Some Models are different by swing width and swing pattern.
1.0˚C(2˚F) up
1.0˚C(2˚F) up
Sleep time ( hour )
0.5
1
- 14 -
Step
Description
SL
Super Low
L
Low
ML
Medium-Low
M
Medium
MH
Medium-High
H
High
SH
Super High
Auto
Natural Wind