Conversion Table; Multi-System Setup Example - Honeywell W8150 User Manual

Fresh air ventilation system, fresh air ventilation control
Table of Contents

Advertisement

Y8150 FRESH AIR VENTILATION SYSTEM, W8150 FRESH AIR VENTILATION CONTROL
HVAC
R
C
W
W
1
2
HE440
FAN
R
R
C
C
Tue
Wake
Fig. 10. Wiring fan for a steam humidifier.

Multi-System Setup Example

Total square feet and bedrooms should be proportionately
split between the ventilation controls based on sq ft served by
each system regardless of where the bedrooms are located.
Example: 5,000 sq ft, six bedrooms:
System 1:
• serves 3200 sq ft,
• two bedrooms.
• fresh air intake measured at 127 cfm.
System 2:
• serves 1800 sq ft,
• four bedrooms
• fresh air intake measured at 98 cfm.
Set W8150 for System 1:
• 3100 sq ft,
• four bedrooms
• 130 cfm.
Set W8150 for System 2:
• 1900 sq ft,
• two bedrooms
Automation and Control Solutions
Honeywell International Inc.
1985 Douglas Drive North
Golden Valley, MN 55422
Honeywell Limited-Honeywell Limitée
35 Dynamic Drive
Toronto, Ontario M1V 4Z9
customer.honeywell.com
Y
Y
G
1
2
W8150A
G
F
R
C
C
C
C
H
W
G
T
RED
BLACK
R8222
BLUE
BLUE
W
W
Y
Y
G
1
2
1
2
System
Heat
AM
Fan
Room
DST
Auto
M22021A
• 100 cfm.

CONVERSION TABLE

Area
sq ft
1000
1300
1600
1900
2200
2500
2800
3100
3400
3700
4000
4300
4600
cfm
fpm
40
204
50
255
60
306
70
357
80
407
90
458
100
509
110
560
120
611
130
662
140
713
150
764
160
815
® U.S. Registered Trademark
© 2011 Honeywell International Inc.
68-0282—07 T.D. Rev. 02-11
Printed in U.S.A.
Airflow
sq m
cfm
93
40
121
50
149
60
177
70
204
80
232
90
260
100
288
110
316
120
344
130
372
140
399
150
427
160
Airflow
6 in. duct
7 in. duct
(15.2 cm)
(17.8 cm)
ms
fpm
1.0
150
1.3
187
1.6
225
1.8
262
2.1
299
2.3
337
2.6
374
2.8
412
3.1
449
3.4
486
3.6
524
3.9
561
4.1
599
lps
19
24
28
33
38
42
47
52
57
61
66
71
76
ms
0.8
1.0
1.1
1.3
1.5
1.7
1.9
2.1
2.3
2.5
2.7
2.9
3.0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Y8150

Table of Contents