Honeywell W8150 User Manual page 7

Fresh air ventilation system, fresh air ventilation control
Table of Contents

Advertisement

Setting the control...
1. Be sure power is turned on.
2. Set the Ventilation Standard on the control.
3. Set the bedrooms dial.
4. Set the area (sq ft) dial.
5. Set the airflow (cfm) dial.
6. Press the test button and observe the lights:
Green light is flashing.
The dial settings meet the chosen standard.
Red light is flashing.
There is not enough fresh air delivered to meet the
requirements of the selected standard. See
Troubleshooting section.
7. Record settings on the label inside the cover as shown
in the diagram.
W8150A 1001
Date installed:________________________
G
R
F
24 VAC
R
C
C
XFRM
60%
ASHRAE 62.2
HVAC
C
DMP
C
Damper
C
DMP
H
W
AUX
ERV/Fan
Stat
G
AUX
T
REM
Timer/Switch
_________
REM
bedrooms
Honeywell
Golden Valley, MN 55422
www.honeywell.com/yourhome
50001159-001 Rev. A
or call 1-800-468-1502
Y8150 FRESH AIR VENTILATION SYSTEM, W8150 FRESH AIR VENTILATION CONTROL
W8150A 1001
G
R
F
R
C
C
HVAC
C
DMP
C
C
DMP
H
W
AUX
Stat
G
AUX
T
REM
REM
Ventilation Limit*
1
100%
2
62-1999
Ventilation
Installer
Standard
Test
_________
_________
area (sq. ft.)
airflow (cfm)
R ecord settings above
Para españ o l ver las instrucciones
*See Instructions
Voir mode d'emploi en franç a is inclus
Customizing the ventilation control.
TIPS:
• Ventilation control reads new dial setting only when test
button is pushed or power is cycled. To ensure dial settings
are read, push test button after any changes are made.
• For single bedroom homes, set the bedrooms dial to 2 (this
may result in more ventilation than the minimum required).
• For homes having more than five bedrooms and only a
single ventilation system, set the bedrooms dial to 5 (this
may result in less ventilation than the minimum required).
• For conditioned square feet, set area (sq ft) dial to the
nearest value.
• For airflow, set airflow (cfm) dial to the nearest value.
• Vaulted ceilings do not need to be considered when setting
this control.
• For homes with multiple systems: Honeywell recommends
a ventilation control and fresh air intake for each system.
Measure ventilation airflow for each system independently.
Refer to Multi-system Setup Example for further details.
Date installed:________________________
Ventilation Limit*
24 VAC
XFRM
60%
ASHRAE 62.2
Damper
Ventilation
Standard
ERV/Fan
Timer/Switch
_________
bedrooms
7
1
100%
2
62-1999
Installer
Test
_________
_________
area (sq. ft.)
airflow (cfm)
Record settings above
M19991