%Gap Adjust Control

Gap Adjust Control
The Gap Adjust LSI receives stroke length information for all of the printhead pins from the sensor analog
circuit. The Gap Adjust LSI then sets the optimum printhead gap for the printing medium.
NOTE:
Refer to Section 2.2.03 for a decription of the mechanical process.
All values in the below chart are in millimeters
ML520/521 ( 96-02-04 )