2.2 Option button
This button rewrites the EEPROM in this printer.
Option menu items will be displayed classified into the following 3 types in functional unit.
(1) EEPROM Operation
(2) H/W Check
(3) Product Set
If pressing the Option button, the Option Menu Dialog will appear as shown in the following figure,
ready for the input from user.
The details of the figure are as follows.
<Reset Engine> button
All the items in Engine Menu will be reset except for LED Head settings to the factory default
(currently, "Print Position" and "Setting"), clearing the counters to zero. This is the equivalent
function to "Engine Reset" (Engine Maintenance Mode) for OL600e/610e. However, the items
which have been selected disable by the initial file cannot be initialized even in other settings than
LED Head. Nor for counters, can the counters be cleared if they have been set disabled.
<Upload> button
Settings in Engine Menu and numbers in counters will be saved to the memory for a currently-
connected printer. After saving them, "EEPROM Download" will become valid.
However, when an I/F error has been detected, a message box informs the user of it without
reading data from EEPROM.
<Download> button
The settings in Engine Menu and numbers in counters, which have been saved to the memory
at "EEPROM Upload" selection, will be sent as commands to printer for EEPROM settings. After
the completion of transmitting them, this button will become invalid.
However, when an I/F error has been detected, a message box informs the user of it without
writing data to EEPROM.
displays and changes the engine menu settings.
performs a H/W check for the printer.
changes the model name of printer, destination for shipment