SilverStone ST70F-ES Specification

SilverStone ST70F-ES Specification

Strider essential series atx12v 2.3 switching power supply with active pfc ps/2

Advertisement

Strider Essential Series
ST70F-ES / ST60F-ES
Power for everything you need
High efficiency with 80Plus certification
o
24hour continuous power output with 40 C operating temperature
Class-leading single +12V rail
Multiple protection circuitry
November, 2010
Silent running 120mm fan with 18dBA
NO. G1121
PCI-E 8pin and PCI-E 6pin connector support
ATX 12V 2.3 support
Active PFC circuitry

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ST70F-ES and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SilverStone ST70F-ES

  • Page 1 Strider Essential Series ST70F-ES / ST60F-ES Power for everything you need High efficiency with 80Plus certification 24hour continuous power output with 40 C operating temperature Class-leading single +12V rail Multiple protection circuitry November, 2010 Silent running 120mm fan with 18dBA NO.
  • Page 2: Specification

    Strider Essential Series SPECIFICATION 2.2 Input Frequency SilverStone Essential Plus 2.2.1 ST70F-ES ST70F-ES Nominal Frequency Frequency Variation Range 50-60 Hz 47 Hz to 63 Hz ST60F-ES 2.2.2 ST60F-ES ATX12V 2.3 Switching Power Supply Nominal Frequency Frequency Variation Range With Active PFC...
  • Page 3 Strider Essential Series STRIDER ST1000 STRIDER ST1000-NV 3.1.2 ST60F-ES 2.5 Efficiency Output Load Range Ripple ST70F-ES, ST60F-ES provides an efficiency of >80% when measured at full load Peak Regulation Voltage P-P Max under 115V/60Hz and 230V/50Hz condition. 1. +5V 0.2A ±5% 70mV 3.
  • Page 4 +5 VDC and +3.3 VDC outputs are above the under-voltage thresholds of the power supply. When this signal is asserted high, there should be sufficient mains energy 3.3.1 ST70F-ES stored by the converter to guarantee continuous power operation within specification.
  • Page 5: Start Stability

    5.1 No Load Start 4.1 Input Protection When power is applied to ST70F-ES & ST60F-ES with no load connected or under minimum load connected, neither damage to power supply nor hazards In primary circuit of the power supply, a protected fuse is inserted. Only internal to users will occur.
  • Page 6: Conducted Emi

    Strider Essential Series 6.3 Vibration and Shock Time Diagram 6.3.1 Sweep and resonance search for each of X,Y,Z, axis at the sweep. Frequency Duration Amplitude 5-55-10 Hz 30 minutes 0.35 mm 7. CONDUCTED EMI FCC, CE 8. PRODUCT SAFETY 8.1 Safety Requirement TUV, UL/c-UL,CB T1 : Turn on time ( 2 sec.
  • Page 7: Power Factor

    Strider Essential Series 13. Power Factor ATX 12V 4PIN (4+4PIN EPS 12V in split mode) The power supply with active power factor correction, and meet the EN61000-3-2 Signal Signal standards, The power factor is greater than 0.9 at 230V/50Hz, Max. load. Black +12V Yellow...