EPSON ELP-3500 Service Manual
3.2.13 Removing the Lamp Outer Housing Unit
Prerequisite: Complete the steps explained in sections 3.2.1 and 3.2.6.
1. Remove 2 lamp air guide mounting screws to detach the lamp air guide.
Screws:
2. Remove the lamp outer housing unit mounting screws and remove the lamp outer
housing unit.
Screws:
Caution:
The interior of the lamp outer housing is susceptible to dust, if necessary, clean it before
reinstalling it. The lamp outer housing remains hot for a while after power is turned off.
Remove the housing after it cools down completely.
Screws
Figure 3-22.
Screw
Figure 3-23.
+M3x8 F/Zn P-Tight: P/N 1021824
Mounting torque: 6.0 kg cm = 5.2 lb inch
+M3x8 F/Zn: P/N 1021824
Mounting torque: 6.0 kg cm = 5.2 lb inch
Lamp Air Guide
3-19