Brother HL-2030 Service Manual page 204

Laser printer
Hide thumbs Also See for HL-2030:
Table of Contents

Advertisement

CHAPTER 7 TROUBLESHOOTING
I-17
Black band
Possible cause
Corona failure
Corona dirty
I-18
Gray background
Possible cause
Print paper
Toner sensor
failure
(printer side)
Toner cartridge
failure
Drum unit failure
NOTE:
The following cases increase the possibility of this problem.
• Acid paper is being used.
• The drum unit is at the end of its life.
• There is dust or paper powder.
Step
Check
1
Is the wire cleaner at its home
position?
2
Is the corona wire dirty?
Step
Check
1
Does the paper being used
meet the paper specification
(weight, etc.).
2
Is Ready LED still lighted after
the toner cartridge and drum
unit are taken out? (The front
cover is closed.)
3
Is the problem solved after
replacing the toner cartridge?
4
Is the problem solved after
replacing the drum unit?
Result
No
Return the wire cleaner
to its home position.
Yes
1) Clean the corona
2) If the problem still
Result
No
Recommend to use the
specified types of paper.
Yes
Recommend to change to
freshly unpacked paper.
Yes
Toner sensor failure. Clean the
toner sensor and check the
toner sensor connection.
Yes
Replace the toner cartridge.
Yes
Replace the drum unit.
No
Replace the high-voltage power
supply PCB.
7-40
Remedy
contacts
wire.
appears after
cleaning, replace
the drum unit.
Remedy
Confidential
Ground
(2)
(2)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hl-2040Hl-2070nHl-2032Hl-2037Hl-2035

Table of Contents