3.1
Cleaning Materials and Locations requiring
Cleaning
■ Cleaning Materials
Cleaning Materials
Cleaner F1
Cleaning Wipe
PFU LIMITED
Lint-free dry cloth
For details about the cleaning materials, contact the FUJITSU scanner dealer where you
purchased the scanner.
*1) It may take long before the cleaner vaporizes if a large quantity is used. When cleaning
the scanner parts, dampen a cloth with modest quantities of the cleaner. In addition, wipe
off the cleaner completely with a soft lint-free cloth to leave no residue on the surface of
the cleaned parts.
■ Locations and Cycle for Cleaning
The following table shows a standard cycle provided as a guide for cleaning each location.
Pad ASSY
Pick roller
Feed rollers
Plastic rollers
Eject rollers
Sheet guides
Glass
Ultra sonic sensor
78
Parts Number
PA03950-0352
(*1)
PA03950-0419
- Commercially available one
Part to clean
1 bottle
Moisten a cloth with this fluid and wipe the
scanner clean.
24 sheets/pack
Pre-moistened with Cleaner F1, Cleaning
Wipes are used instead of moistened cloths.
Standard Cleaning Cycle
Clean these parts after every 5,000 scans.
Remarks