Initial Start-Up/Generator Operation - MULTIQUIP GA-6REA Operation And Parts Manual

Robin gasoline engine
Table of Contents

Advertisement

GA-6RE/GA-6REA — INITIAL START-UP/GENERATOR OPERATION
7. If the engine has started, slowly return the choke lever
(Figure 12 ) to the "OPEN" position. If the engine has not
started repeat steps 1 through 5.
8. Before the generators is placed into operation, run the
engine for 3-5 minutes. Check for abnormal smells, fuel
leaks, and noises that would associate with lose compo-
nents.
9. Place the idle control switch (Figure 16) in the "OFF"
(down) position. This will allow the engine speed to run
at speed about 3600 RPM's
Figure 16. Idle Control Switch (Off)
NOTE
the generators will run at idle speed (2200 RPM's) until a load is
applied, at that time the engine speed will increase to 3600
RPM's as long as the load is being applied. When the load is not
in use, the engine speed will drop back to the idle mode after
about 3 seconds.
Figure 17. Idle Control Switch (On)
60 Hz Operation
1. Place main circuit breaker (Figure 18) in the ON position.
Figure 18. Main Circuit Breaker (ON)
PAGE 26 — GA-6RE/GA-6REA A.C. GENERATORS — OPERATION & PARTS MANUAL — REV. #0 (06/06/05)
Placing the idle control switch in
the OFF position (Figure 16) allows
the engine to operate at a maximum
speed of about 3600 RPM's. When
the idle control switch is placed in
the up position (ON) (Figure 17),
2. Place the full power switch (Figure 19) in the 120V
position (up).
Figure 19. Full Power Switch 120 V Position (Up)
When the full power switch is in the 120 V
position, the 240V twist-lock receptacle
NOTE
cannot be used.
3. Read the voltmeter on the front panel of the generators
(Figure 20) and verify that120 VAC is present at the
120V twist-lock and GFCI duplex receptacles. For
additional verification of voltage, an external voltmeter
can be used to measure the output voltage as shown in
Figure 20.
Figure 20. 120 V and GFCI Receptacles
4. Place the full power switch (Figure 21) in the 240V
position (down).
Figure 21. Full Power Switch 240/120 V Position (Down)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ga-6re

Table of Contents