Electrical Connection; Alarm Output Connection - Omega OS101 User Manual

Os100 series mini-infrared transmitter
Hide thumbs Also See for OS101:
Table of Contents

Advertisement

2
OS100 Series - Installation
The following describes the ordering information:
The following optional accessories are available:
Here are the Features of OS101 and OS102 infrared transmitters:
2.2

Electrical Connection

Sensor Head Cable - The Sensor head is pre-wired to a 1.8 m (6 feet)
shielded cable. Plug & lock-in the male connector to the mating female
connector on the aluminum housing.
Power & Output Connection - Open the cover of the main aluminum
housing. Slide the cable through the strain relief and connect the wires to
the terminal block on the board as shown in Fig. 2-1. For Alarm output
connection, refer to Fig. 2-2.
2-1
OS102 or OS101 - MA - *, **, where
MA - 4/20 mA output
V1 - 0 to 5 VDC output
K - Thermocouple output, K type
MV - Millivolt output
Model No.
OS100-MB
OS100-DR
OS100-WC
OS100-AP
OS100-LS
OS100-CA15FT
OS100-CA25FT
TX8-100
PSU-93
CAL3-IR
Features
Accuracy
Temp Range
Emissivity
Field of View
Alarm Output
1mV/Deg. Output
4-20mA Output
0/5 VDC Output
K Type T/C
LED Display
Main Housing
C - 1 mV/°C output
F - 1 mV/°F output
Description
Mounting Bracket
DIN Rail Mounting adapter
Water Cooling jacket
Air purge collar
Laser Sighting
Sensor Head Extension Cable (4.6 m, 15")
Sensor Head Extension Cable (7.6 m, 25')
8 Conductor stranded Shielded cable (30 m, 100')
Unregulated 16-24 VDC Power Supply
NIST Traceable Calibration
OS101
2% Rdg or 4°F (2.2°C)
0-1000°F (-18 to 538°C)
0.1 to 0.99 Adj.
Standard
Standard
Standard
Standard
Std.
––
65.5 x 30.5 x 115.3 mm
(2.58" x 1.2" x 4.54")
HT- High
temperature
sensor head
OS102
6 to 1
––
Std.
65.5 x 55.9 x 115.3 mm
2.58" x 2.2" x 4.54"