Download Print this page

Technical Specifications - HP ProLiant BL685c Quickspecs

Server blade
Hide thumbs Also See for ProLiant BL685c:

Advertisement

QuickSpecs

Technical Specifications

System Unit
System Unit
System Unit
System Unit
Dimensions
Dimensions
Dimensions
Dimensions
(H x W x D)
Shipping Dimensions
Shipping Dimensions
Shipping Dimensions
Shipping Dimensions
(H x W x D)
Weight
Weight
Weight
Weight
(approximate)
Power Specifications
Power Specifications
Power Specifications
Power Specifications
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature Operating
System Inlet Temperature
Relative Humidity
Relative Humidity
Relative Humidity
Relative Humidity
(non-condensing)
Altitude
Altitude
Altitude
Altitude
Acoustic Noise
Acoustic Noise
Acoustic Noise
Acoustic Noise
DA - 12576
Worldwide — Version 23 — December 15, 2008
14.42 x 2.19 x 20.058 in (36.63 x 2.19 x 50.95 cm)
21.50 x 9.94 x 23.13 in (54.61 x 25.25 x 58.75 cm)
Maximum
(all hard drives and
processors installed)
Minimum
(one hard drive and
processor installed)
For power specifications including input requirements, BTU rating, and
power supply output, please see the HP BladeSystem c-Class Enclosures
QuickSpecs located at:
HP BladeSystem c3000 Enclosure QuickSpecs:
http://h18000.www1.hp.com/products/quickspecs/12790_div/
12790_div.html
HP BladeSystem c7000 Enclosure QuickSpecs:
http://h18000.www1.hp.com/products/quickspecs/12810_div/
12810_div.html
To review typical system power ratings use the HP BladeSystem Power Sizer
available at: http://www.hp.com/go/bladesystem/powercalculator.
Non-operating
Operating
Non-operating
Operating
Non-operating
For acoustic noise specifications, please see the HP BladeSystem c-Class
Enclosures QuickSpecs located at:
HP BladeSystem c3000 Enclosure QuickSpecs:
HP ProLiant BL685c Server Blade
HP ProLiant BL685c Server Blade
HP ProLiant BL685c Server Blade
HP ProLiant BL685c Server Blade
22.8 lbs (10.3 kg)
19.35 lbs (8.75 kg)
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed. System performance may be reduced if
operating with a fan fault or above 30°C (86°F).
-30° to 60°C (-22° to 140°F), maximum rate of
change is 20°C/hr (36°F/hr).
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
10 to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature, non-
condensing.
3050 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500 ft/min).