Sharp UX-A255U Service Manual page 24

Facsimile machine
Table of Contents

Advertisement

UX-A255U
SW-I7 No. 3, No. 4 AGC slew rate (Mic)
The AGC Slew Rate controls the convergence of the message playback
level to the desired playback level. A large slew rate will allow faster
convergence and a small slew rate will allow slower convergence.
SW-I7 No. 5 ~ No. 8 Reserved
Set to "0".
SW-J1 No. 1, No. 2 Reserved
Set to "0".
SW-J1 No. 3 Sender's phone number setting
Used to make a choice of whether the registered sender's phone number
can be changed or not. If the switch is set to "1", new registration of the
sender's phone number is disabled to prevent accidental wrong input.
SW-J1 No. 4, No. 5 Reserved
Set to "0".
SW-J1 No. 6 Summer time setting
This is used to set YES/NO of automatic clock adjustment for daylight
saving time.
SW-J1 No. 7, No. 8 Ringer volume
Used to adjust ringing volume.
SW-J2 No. 1 ~ No. 3 Reserved
Set to "0".
SW-J2 No. 4, No. 5 Handset receiver volume
Used to adjust the a handset receiver volume.
SW-J2 No. 6 ~ No. 8 Speaker volume (5 stages)
Used to adjust sound volume from a speaker.
SW-J3 No. 1 Reserved
Set to "0".
SW-J3 No. 2 ~ No. 4 Communication result printout (Transaction
report)
Every communication, the result can be output. As usual, it is set to print
the timer sending communication error alone. If No. 2: 0 No. 3: 1 No. 4:
0 are set, printing is always on (printed even if it is normally ended).
000: Error, timer and memory sending/receiving
001: Sending
010: Continuous printing
011: Not printed
100: Communication error
SW-J3 No. 5 ~ No. 8 OGM/ICM output level to speaker
(0dB ~ -15dB) (1dB step)
Used to control OGM and ICM output level to speaker.
SW-K1 No.1, No. 2 Reserved
Set to "0".
SW-K1 No. 3 ~ No. 8 OGM/ICM output level to Line
(0dB ~ -32dB) (1dB step)
Used to control OGM and ICM output level to Line.
SW-L1 No. 1 ~ No. 4 Reserved
Set to "0".
SW-L1 No. 5 Cut off mode (COPY mode)
Whether the excessive part is printed on the next recording paper or
discarded is selected to copy a document which is longer than the re-
cording paper.
SW-L1 No. 6 A4 Paper enable
The use of recording paper of A4 is enabled.
SW-L1 No. 7 LEGAL and LETTER paper enable
The use of recording paper of LEGAL and LETTER is enabled.
SW-L1 No. 8 Reserved
Set to "0".
SW-L2 No. 1, No. 2 Paper set size
At present size of the recording paper.
SW-L2 No. 3 Automatic reduce of receive
If set to 1, it is reduced automatically when receiving.
SW-L2 No. 4 ~ No. 6 Print contrast
Used for adjustment of print contrast.
SW-L2 No. 7 Reception reduction ratio in case of memory full
This model is designed so that the print is started according to the set-
ting of SW-L2 No.3 when reception of one page is completed. However,
if the memory is filled with data before completion of reception of one
page, the print is started with the reduction ratio which is set with this
switch.
SW-L2 No. 8 Reserved
Set to "0".
SW-M1 No. 1 ~ No. 8 Reserved
Set to "0".
SW-M2 No. 1 ~ No. 8 Reserved
Set to "0".
SW-N1 No. 1 ~ No. 6 LCR short time
First time setting transmitting to the Open LCR center.
SW-N1 No. 7, No. 8 Reserved
Set to "0".
SW-N2 No. 1 ~ No. 6 LCR long time
Second time setting transmitting to the Open LCR center.
SW-N2 No. 7, No. 8 Reserved
Set to "0".
SW-N3 No. 1 LCR Time Select
Used to select LCR short time or LCR long time.
0:LCR short time is selected.
1:LCR long time is selected.
SW-N3 No. 2 Temporary release of caller ID withhold
Used to do temporary release of caller ID withhold.
0:Normal dialing.
1:Release of caller ID withhold before dialing.
SW-N3 No. 3 Connect Japanese center
Used to connect Japanese open LCR center.
0:Connect USA open LCR center.
1:Connect Japanese open LCR center.
SW-N3 No. 4 Open LCR debug mode
Used to debug open LCR function.
0:Normal mode.
1:debug mode.
SW-N3 No. 5, No.6 Digital line equalization setting (Open LCR
downloading)
Line equalization when Open LCR downloading is to be set according to
the line char-acteristics. Setting should be made according to distance
between the telephone and the telephone company central switching
station.
SW-N3 No. 7 Relese code of Caller ID withhold for tone or pulse
line.
Used to connect Open LCR server.
"0": *82 (for TONE)
"1": 1182 (for PULSE)
SW-N3 No. 8 Reserved
Set to "0".
2 – 18

Hide quick links:

Advertisement

Table of Contents
loading