Replacing Damaged Hard Drives; Hard Drive Damage; Replacing A Hard Drive; Raid Auto-Rebuild - Thecus 1U4600 User Manual

Hide thumbs Also See for 1U4600:
Table of Contents

Advertisement

Replacing Damaged Hard Drives

If you are using RAID 1, RAID 5, or RAID 6 you can easily replace a damaged hard
drive in the Thecus 1U4600 while keeping your data secure with the system's
automatic data recovery.

Hard Drive Damage

When a hard drive is damaged and data in the RAID volume, the system LCD will
display warning message also the system beeps.

Replacing a Hard Drive

To replace a hard disk drive in the 1U4600:
1. Remove the tray with the damaged hard disk.
2. Unscrew the damaged hard disk and remove it from the tray.
3. Slide a new hard disk into the tray and fasten the screws.
4. Insert the hard disk tray back into the 1U4600 until it snaps into place. You
can also lock it with a key if desired.
5. The LED blinks green when the HDD is accessed.

RAID Auto-Rebuild

When using RAID 1, 5, 6, or 10 on the 1U4600, you can use the auto-rebuild
function when an error is detected.
1. When a hard disk fails the system beeps and/or an email notification is sent
to specified receivers.
2. Check the LCD to see which disk has failed.
3. Follow the steps mentioned above to replace the failed hard disk.
4. The system automatically recognizes the new hard disk and starts the
auto-rebuild sequence to resume its status before the hard disk crash.
115

Advertisement

Table of Contents
loading

Table of Contents