The AC power portion of the circuit appears ok
Disconnect the AC Adapter once the battery has charged for 5 minutes or so.
Press and hold the <FEED> switch, then press and release the <ON/OFF>
switch and then release the <FEED> switch. The printer will print a "self test"
receipt
If the self test receipt is printed, the DC power is ok
Press <ON/OFF> switch and wait until all LED's are off
Plug the AC adaptor into the printer. Press <ON>; the green LED is
illuminated and after about 20 seconds the LED should go off
If the amber LED is on, this will continue on through this test indicating that
the battery is accepting a charge and that the charge circuit is ok. At the end
of a 180 minute charge cycle the LED will go off.
4.4 Battery and Safety Information:
The printer is powered by a 7.4V Li-Ion battery cartridge.
Charging time in the printer is approximately 3.0 hours
Take the battery out of printer if storing the printer for long periods of time
The battery storage temperature is 40°F to 104°F (4°C to 40°C). Do not
store a fully charged battery at temperatures greater than 104°F (40°C) for
long periods of time – the battery may permanently lose charge capacity
Be sure to use a fully charged battery before long or battery intensive
printing sessions. Certain operations (for example, printing receipts with a lot
of bar codes and graphics) drain the battery more quickly than others
Dispose according to your local regulations. Do not throw in trash
Caution: Do not disassemble, short circuit, heat above 80°C, or
incinerate. The battery may explode
The recommended temperature for charging is between 68°F (20°C) to 77°F
(25°C).
4.5 Recycling your Batteries:
The Rechargeable Battery Recycling Corporation (RBRC) is a non-profit organization
created to promote recycling of rechargeable batteries. For more information about
how to recycle batteries in your area, visit www.rbrc.org.