Dip Switch Functions - Extech Instruments APEX 2 User Manual

Portable printer
Table of Contents

Advertisement

3.2.3 Dip Switch Functions

Table 2 shows the available dip switch settings.
Dip
Switch
1 & 2
Communication Interface
3 & 4 & 5
6
Parity Enabled
Parity Disabled
7
Even Parity Checker
Odd Parity Checker
8
Auto Power Save
Power Save Disabled
Power Save Enabled
Note: In order for changes to the dip switch configuration to take effect, the printer power must
be reset. This action occurs automatically when the battery is removed to gain access to the dip
switches. Please refer to the Developer's Manual for more information
APEX2 User's Guide
Table 2 – DIP Switch Setting
Switch #
Function
SW 1
OFF
RS232
ON
IrDA
Bluetooth
OFF
OFF
802.11g
SW 3
Baud Rate
OFF
115200
57600
ON
38400
OFF
ON
19200
OFF
14400
ON
9600
2400
OFF
ON
1200
SW 6
Parity Bit
ON
OFF
SW 7
Odd/Even
ON
OFF
SW 8
OFF
ON
Switch
Switch
#
#
SW 2
OFF
OFF
value specified through Dip switches 3,4
ON
ON
SW 4
SW 5
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
ON
ON
ON
ON
Rev 1.0
Notes
Baud rate set by Dip switches 3,4 and 5
Baud Rate can be negotiated up to the
and 5
Use for fixed IrDA
Does not apply for IrDA
Does not apply for IrDA
Does not apply for IrDA
Does not apply for IrDA
Manual On/Off
Auto Power Down
15