Download Print this page

Professional Service - Redring Active Installation And User Manual

Electric shower

Advertisement

SELF HELP
If the shower is not working satisfactorily, make
the following checks before calling out the
installer.
Any one of these adjustments could restore the
performance.
The shower temperature is set too
hot causing the thermal cut-out
(safety device) to operate.
Turn Knob 'B' anti-clockwise to
increase water flow.
Shower
Slowly increase the water
cycles
temperature by turning Knob 'B'
from
clockwise until a comfortable
HOT to
showering temperature has been
COLD
reached.
You MUST WAIT approximately
20 seconds for each adjustment to
affect the water temperature.
'Economy' setting (two red bars)
may need to be selected.
Increase water flow by adjusting
Knob 'B' anti-clockwise.
'Economy' setting (two red bars)
Water
may need to be selected.
too
Increase pressure to water supply.
HOT
Fully open service valve/stop cock.
Check hose is not kinked restricting
the water flow.
Clean shower handset.
Decrease water flow by adjusting
Water
Knob 'B' clockwise.
too
'High' setting (three red bars) may
COLD
need to be selected.
Thermal cut-out has operated after
Water
previous use (automatically resets
takes
when unit cools down)
longer
'High' setting (three red bars) may
to heat
need to be selected.
up
Check water pressure has not fallen
Water
so far as to let the pressure switch
goes cold
cut out.
whilst
using
e.g. Another tap drawing water off.
shower
Spray
Clean the shower handset.
pattern
poor
Please contact us on our after sales
Broken
service department (See Section 5).
parts
Fitting instructions are provided
with most spares

PROFESSIONAL SERVICE

If the previous 'Self Help' checks fail to restore
performance, you should seek professional help.
The person who installed the shower is probably
the best one to investigate and correct it and is
certainly the person to contact if you have had a
problem in the guarantee period.
The following additional checklist is provided for
the benefit of the qualified service person.
WARNING:
SWITCH OFF THE ELECTRICITY AT
THE LOCAL ISOLATOR BEFORE
REMOVING THE COVER TO MAKE
CHECKS.
Water flow restricted by blockage
in filter of solenoid valve.
Water
Switch off water, remove solenoid,
too
check and clean inlet filter.
HOT
Replace solenoid valve if blocked.
Check circuit through
thermal cut-out.
Check circuit through
Water
microswitches on the pressure
too
switch.
COLD
Check each element circuit.
Check tightness of electrical
connections.
Undo headworks of stabiliser valve
No control
Check stabiliser is in place and
over
water flow
remove any debris in valve.
Check for cause of high pressure
Water
and remove it.
discharges
Blockage on outlet e.g. blocked
from
shower handset.
pressure
relief valve
Replace the pressure relief device.
Check circuit through solenoid coil.
Water
If defective then replace.
does not
Check circuit through
flow when
microswitches.
Knob 'A'
If defective then replace.
turned.
Power supply not reaching shower
9

Advertisement

loading