8
APPENDICES
8.1 GENERAL TECHNICAL SPECIFICATIONS.
Nominal power (kVA)
INPUT
Nominal voltage
Input voltage margin
Frequency
Input current total harmonic
distortion
Current limit
Power factor
INVERTER
Nominal voltage
Precision
Frequency
Max. synchronisation speed
Wave form
Output
voltage
total
distortion
Phase displacement
Dynamic recovery time
Admissible overload
Admissible crest factor
Admissible power factor
Imbalance output voltage with load
100 % unbalanced
Current limit
STATIC BYPASS
Type
Voltage
Frequency
Transfer time
Admissible overload
Transfer to bypass
Retransfer
MANUAL BYPASS (maintenance)
Type
Voltage
Frequency
GENERAL
Overall efficiency
DIMENSIONS & WEIGHT (cabinet ups)
Depth x Width x Height (mm) /
equipped with castors
Weight (no batteries) (kg)
Built-in 2x31 batteries 12 V (Ah)
Weight (with built-in batteries) (kg)
Batteries terminal torque
Table 5. Technical specifications
INFOSEC UPS SYSTEM - 4, rue de la Rigotière - 44700 Orvault - FRANCE - www.infosec-ups.com
Hot Line – Tel + 33 (0)2 40 76 15 82 - Fax + 33 (0)2 40 94 29 51 - hotline@infosec.fr – 03 11 AA AA 201 18
10
100 % load: THDi < 1.5 %.
50 % load: THDi < 2.5 %.
10 % load: THDi < 6.0 %.
Static variation: ±1 %. Dynamic variation: ±2 % (load variations 100%-0%-100 %).
harmonic
Linear load: THD-v < 0.5 %. Ref. non-linear load (EN-62040-3): THD-v < 1.5 %.
120 ±1 % (balanced load). 120 ±2 % (imbalances 50 % of the load).
3.4 to 1.
High overload, short-circuit: RMS voltage Limit. High Crest-Factor current: Peak Voltage Limit.
90.5 %
700 x 450 x 1100 / YES.
7
15
20
Three phase 3x380 V, 3x400 V or 3x415 V (4 wires: 3 phases + N).
+ 15% / –20%.
50 / 60 Hz ±5 %.
High overload: PFC Limit (discharging batteries).
1.0 (at any load condition).
Three phase 3x380 V, 3x400 V or 3x415 V (4 wires: 3 phases + N).
Synchronised: 50/60 Hz ±4 % / Battery mode 50/60 Hz ±0.05 %.
±1 Hz/s.
Sine-wave.
10 ms. at 98 % of the static value.
125 % for 10 min., 150 % for 60 s.
0.1 inductive to 0.1 capacitive.
< 1 %.
Microprocessor-controlled static system
Three phase 3x380 V, 3x400 V or 3x415 V (4 wires: 3 phases + N).
50 / 60 Hz
400 % for 10 sec.
Immediate, for overloads above 150 %.
Automatic after alarm clear.
Without interruption.
Three phase 3x380 V, 3x400 V or 3x415 V (4 wires: 3 phases + N).
50 / 60 Hz.
90.5 %
91.0 %
92.0 %
120
7
9
250
Depending on battery manufacture.
30
40
100 % load: THDi < 1.0 %.
50 % load: THDi < 2.0 %.
10 % load: THDi < 5.0 %.
3.2 to 1.
Zero
92.5 %
93.05 %
805 x 590 x 1320 / YES.
190
12
18
530
60
80
2.8 to 1.
94.0 %
200
300
-
-
-
-
43