Place and Level Range

!
CAUTION
To avoid damaging oven door, do not lift or move range
by oven door handle. Glass can break.
Plug in range. Slide range into place. Carefully level range
using legs provided. Range must be level to cook and
bake uniformly.
• Place a level on top oven rack or on top of range when
leveling.
• Leveling legs must be extended out ¼ inch to engage
anti-tip bracket.

Removal and Replacement of Range

1. Turn off gas, and disconnect gas and power to range.
2. Slide range forward.
3. Unplug range cord and place range aside.
4. Remove anti-tip bracket.
5. Install anti-tip bracket into new location using
instructions provided with bracket or see Anti-tip
Bracket Installation section in this manual.
6. To reinstall range, follow instructions in Installation
section of this manual.
Test and Adjust Oven Burner and Broiler
Flame
Turn on oven burner and broiler. See "Baking" and
"Broling" sections for operating instructions. Properly
adjusted flames are blue with a distinct deep blue inner
cone approximately ½ inch long. Flame should not have
any yellow flame when burning.
Bake burner flame should not be visible in the oven cavity
when burning and should not extend into the oven cavity
beyond the removable oven bottom.
• If burner flame is blowing or noisy, reduce airflow to
burner.
• If burner flame is yellow and does not hold its shape,
increase airflow to burner.
Burner Flame
Adjust Oven Burner Flame
1. Remove storage drawer.
• See "Removing Storage Drawer" section.
2. Locate air shutter behind downdraft vent.
3. Loosen air shutter lock screw and open or close air
shutter.
• Tighten air shutter lock screw after adjusting.
4. Replace cover plate and storage drawer.
A—Air Shutter Lock Screw
B—Orifice Hood
C—Air Shutter
Adjust Air Shutter
Broiler Flame
1. Open oven door and locate air shutter on ceiling of
oven cavity.
2. Loosen air shutter lock screw and open or close air
shutter.
• Tighten air shutter lock screw after adjusting.
1/2"