The four-way valve compensation function is engaged in four cases
When starting the compressor for heating.
When the operation mode is changed.
When starting the compressor for defrosting.
When starting the compressor after a power failure (auto-restart).
No power to the valve --> cooling.
Power to the valve --> heating.
Cooling
Heating
3.4
Compressor Start-up Protection
Details
The gradual buildup of the upper operation frequency is illustrated in the graph below.
Fig. : Compressor protection function graph.
Timers and frequencies for the compressor protection function
Function and Control
outdoor temperature < 16°C(60.8°F)
outdoor temperature 16°C(60.8°F) – 0.9 x outdoor temperature (°C) + 68
Frequency
(Hz)
FCG5
FCG4
FCG3
FCG2
FCG1
TCG1
FCG1
52
FCG2
52
FCG3
58
FCG4
80
FCG5
98
TCG1
450
TCG2
90
TCG3
90
TCG4
60
TCG5
60
Frequency [Hz]
52
52
TCG2
TCG3
TCG4
Control Specification
Time [sec]
60
Time
(sec)
TCG5
(R10093)