Indoor Unit
Step
3
Remove the 2 fixing
screws for heat
exchanger on the left.
4
Lift the left side of the heat
exchanger, and pull
toward yourself.
5
Release the hook through
the gap in the pipes.
6
Slide to right to undo the
hook and lift the heat
exchanger up.
192
Procedure
SiUS04-921
Points
Caution
When dismounting or
mounting the heat exchanger,
be sure to wear gloves or wrap
it with cloth before proceeding
with the work as fins can injure
your hands.
 Be careful so the solenoid
valve will not be caught in the
hook.