Main Functions
2.5
Cooling Breeze Operation
Operation
Effective mode for cooling breeze airflow
Note
In automatic mode, when actual operation mode is heating, this cool air fluctuation operation does
not work. (Indication on remote controller is shown.)
Fin operation
Airflow rate
Refer to the operation manual for details.
1/f fluctuation rhythms switches airflow direction
Features
20
• Auto / Cooling
• QUATERNITY drying
• Dry cooling
• Flash streamer air purifying
As shown in the following graph, the standard point is the upper limit of the swing so that the air
does not touch directly.
Depending on the room temperature or the thermostat on/off state, the swing interval is
changed.
The lower the temperature, the longer the swing interval, thereby comfort is maintained.Left
and right fins move as set on the remote controller.
Airflow rate is controlled automatically.
By fluctuating airflow direction you can feel cool even if the room temperature is set high.
By1/f fluctuation rhythm, upper and lower louvers move up and down unlike the conventional up
and down swing, and this movement brings you comfortable air like breezes in nature.
Swing swaying (for example)
Periodically by 1/f swaying rhythm
Swings from draftless position to the lower limit of swinging
Cooling breeze
Time
SiUS04-921
(R10071
Upper limit of swing
= Draftless position
Lower limit of swing
(R3357)
Function and Control