Designed For Basement and Crawlspace Dehumidification
P/N 4029800 • Serial No.________________________ Install Date:___________
Sold by:
www.sylvane.com
1 (800) 934-9194
For small usage:
INSTALLER'S & OWNER'S MANUAL
HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER
4201 Lien Rd. Madison, WI 53708
P/N 4029800
TOLL-FREE 1-800-533-7533
www.santa-fe-products.com
© 2009 Therma-Stor LLC
sales@thermastor.com
Manual P/N TS-596 10/09

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Santa-Fe Advance 4029800 and is the answer not in the manual?

Questions and answers

Summary of Contents for Therma-Stor Santa-Fe Advance 4029800

  • Page 1 INSTALLER’S & OWNER’S MANUAL HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER P/N 4029800 Designed For Basement and Crawlspace Dehumidification P/N 4029800 • Serial No.________________________ Install Date:___________ Sold by: 4201 Lien Rd. Madison, WI 53708 TOLL-FREE 1-800-533-7533 www.santa-fe-products.com sales@thermastor.com • •...
  • Page 2: Table Of Contents

    Condensate Pump Kit ..............7 C22.2 No. 92 Duct Kit Assembly ...............9 3. Specifications Warranty ..................11 Part Number: 4029800 Precautions Blower: 220 CFM @ 0.0" WG • Do not operate the unit with a cut or frayed power cord. Power: 710 watts @ 80°F and 60% RH •...
  • Page 3: Unit Assembly

    SANTA FE ADVANCE INSTALLER'S AND OWNER'S MANUAL 4. Unit Assembly 5. Installation 4.1 Installing Feet (Optional) 5.1 Location Included with your Santa Fe The Santa Fe Advance can be installed in a variety oflocations to Advance are four leveling feet. It meet the owner’s needs, but should beinstalled directly in the area is important to level the unit for to be dehumidified.
  • Page 4: Electrical Requirements

    SANTA FE ADVANCE INSTALLER'S AND OWNER'S MANUAL 5.2 Electrical Requirements The Santa Fe Advance plugs into a common grounded outlet on a 15-Amp circuit. While operating, it draws less than 7 amps @ 80°F, 60% RH and less than 6 amps @ 75°F, 50% RH. Use of a ground fault circuit interrupter (GFCI) protected circuit is recommended.
  • Page 5: Maintenance

    SANTA FE ADVANCE INSTALLER'S AND OWNER'S MANUAL 7. Maintenance 7.4 Installing Filters 1. Gently slide 1" pleated filter into filter slot. Do not force. CAUTION! If resistance is felt, check alignment for obstructions or debris inside the filter housing. NOTE: Do not operate the unit without the proper filter or with 2.
  • Page 6: Troubleshooting

    SANTA FE ADVANCE INSTALLER'S AND OWNER'S MANUAL Evaporator coil frosted continuously, low dehumidifying capacity. gas is routed from the compressor to the condenser coil. The refrigerant is cooled and condensed by giving up its heat to the 1 Dirty air filter or air flow restricted. air that is discharged from the dehumidifier.
  • Page 7: Condensate Pump Kit

    SANTA FE ADVANCE CONDENSATE PUMP INSTALLATION Optional Accessory: Condensate Pump Kit You will not need this hose adaptor. P/N 4025845 Note: Before attaching pump assembly, ensure that the dehumidifier has leveling feet installed on bottom of unit. If your unit has casters, you will need order a set of leveling feet. Call 1-800-533-7533 and ask for Part Number 4026450.
  • Page 8 SANTA FE ADVANCE CONDENSATE PUMP INSTALLATION Step 5. Attach the 20' drain hose to the condensate pump and route it to a floor drain. Plug in the condensate pump and the assembly is completed. Santa Fe Advance Installer’s & Owner’s Manual www.sylvane.com 1 (800) 934-9194...
  • Page 9: Duct Kit Assembly

    SANTA FE ADVANCE DUCT KIT ASSEMBLY Optional Accessory: Duct Kit P/N 4026055 Santa Fe Advance Duct Kit Assembly Instructions Do not drill any pilot holes into the plastic housing. You may damage the internal components. When installing screws, be careful not to strip. Lightly tighten screws. ATTACHING COLLARS Step 3.
  • Page 10 SANTA FE ADVANCE DUCT KIT ASSEMBLY Santa Fe Advance Duct Kit Assembly Instructions Continued FIGURE 1 FIGURE 2 FRONT DUCT ASSEMBLY TOP DUCT ASSEMBLY 1. Check sealing foam on the front duct assembly. Ensure that 1. Check sealing foam on the top duct assembly. Ensure none has none has come loose.
  • Page 11: Warranty

    Limited Warranty Limited Warranty. Therma-Stor, LLC (“Therma-Stor”) warrants as Customer Responsibilities. As a further condition to obtaining follows: (i) the Santa Fe Advance dehumidifier (“Product”) will be free warranty coverage hereunder, the Customer must send a valid of material defects in workmanship or materials for a period of one warranty claim to Therma-Stor such that Therma-Stor receives (1) year (“One-Year Warranty”) following the date of initial purchase such claim prior to the end of the applicable warranty period.
  • Page 12 Information in this document is subject to change without notice. No part of PO Box 8680 • Madison, WI 53708 this document may be reproduced or transmitted in any form or by any means, Phone: 608-222-5301 • Fax: 608-222-1447 electronic or mechanical, for any purpose, without the express written permission Web: www.thermastor.com •...

Table of Contents