Repairs and Adjustments
REP 8 Shield Controller Assembly
Parts List on:
PL 1
WARNING
Switch off the electricity to the machine. Disconnect the power cord from the customer supply
while performing tasks that do not need electricity. Electricity can cause death or injury. Moving
parts can cause injury.
1. Before removing the Shield Controller Assembly, remove the:
- Side Cover Left,
REP
7.
2. Unplug the all connectors from the Main PBA.
Figure 1
Phaser 3435
5/08
4-25