Installation; Selecting A Site For The Switch; Connecting To Your Network - SignaMax 065-7111F Series User Manual

Compact fiber access switch
Table of Contents

Advertisement

Signamax
™ ™ ™ ™
065-7111F series Compact Fiber Access Switch
Table 1: Port Status
LED
State
Indication
The port has established a valid network connection.
Steady
LNK/
LNK stands for LINK.
The port is transmitting or receiving data.
ACT
Flashing
ACT stands for ACTIVITY.

Installation

Selecting a Site for the Switch

As with any electronic device, you should place the switch where it will not be
subject to extreme temperatures, humidity, or electromagnetic interference.
Specifically, the site you select should meet the following requirements:
The ambient temperature should be between 32 and 104 degrees
Fahrenheit (0 to 40 degrees Celsius).
The relative humidity should be less than 90 percent, non-condensing.
Surrounding electrical devices should not exceed the electromagnetic
field (RFC) standards for IEC 801-3, Level 2 (3V/M) field strength.
Make sure that the switch receives adequate ventilation. Do not block
the ventilation holes on the side of the switch or the fan exhaust port on
the rear of the switch.
The power outlet should be within 6 feet (1.8 meters) of the switch.

Connecting to Your Network

Connect network cables from computers or network segments to the TX (FX)
ports on the back of the unit.
Table 2: Cabling Information
Speed
Connector
100BaseTX
RJ-45
10BaseT
RJ-45
100BaseFX
SC, ST,
MT-RJ,
multimode
VF-45, or LC
100BaseFX
SC
singlemode
4
Port Speed
Cable
Half/Full Duplex
100/200 Mbps
100 m, Category 5 or better
STP/UTP
10/20 Mbps
100 m, Category 3, 4, 5 or
better STP/UTP
100/200 Mbps
Up to 2 km, 50 or 62.5/125 µm
multimode fiber cable
100/200 Mbps
Up to 75 km, 9 or 10/125 µm
singlemode fiber cable
User's Manual