Appendix A — Specifications
92
1D Symbologies Typical Reading Distances With 0.24 cm (0.09 in)
Setback*
Symbology Density
Code 39
0.25 mm (10 mils)
0.5 mm (20 mils)
1 mm (40 mils)
1.4 mm (55 mils)
2.5 mm (100 mils)
Code 128
2.5 mm (100 mils) **
retro-
reflective
EAN 100% 0.33 mm
* Typical reading distances are measured in an office environment (200 lux).
** Minimum distance depends on bar code width and scan angle.
80"
0"
40"
in
160"
128"
100% EAN
contrast UPC
96"
64"
32"
0"
32"
0.25 mm
10 mils
64"
0.5 mm/20 mils
1 mm/40 mils
96"
128"
160"
200
0
100
EX25C Near-Far Range Imager 1D Typical Reading Distances: This graphic
does not include the 0.24 cm (0.09 in) setback for the CK3.
Minimum Distance Maximum Distance
15 cm (5.91 in)
16 cm (6.30 in)
25 cm (9.84 in)
40 cm (15.75 in)
**
15 cm (5.91 in)
120"
160"
200"
240"
280"
2.5 mm/100 mils
300
400
500
600
700
CK3 Mobile Computer User's Manual
135 cm (53.15 in)
280 cm (110.24 in)
550 cm (216.54 in)
720 cm (283.46 in)
1200 cm (472.44 in)
1300 cm (511.81 in)
160 cm (62.99 in)
320"
360"
400"
440"
800
900
1000
1100
1200
480"
400
320
240
160
80
0
80
160
240
320
400
cm