MAINTENANCE AND TROUBLESHOOTING

Inspect and properly tighten all parts of the exercise
cycle regularly. The exercise cycle can be cleaned
with a soft, damp cloth. To prevent damage to the con-
sole, keep liquids away from the console and keep the
console out of direct sunlight.
TIGHTENING THE PEDALS
For best performance, regularly tighten both pedals.
CONSOLE TROUBLESHOOTING
If the console display becomes dim, the batteries
should be replaced. See assembly step 5 on page 6
for replacement instructions. If the console does not
display your heart rate when you use the handgrip
pulse sensor, see step 5 on page 13.
HOW TO LEVEL THE EXERCISE CYCLE
If the exercise cycle
does not sit flat on
your floor, turn one or
both of the leveling
feet until the exercise
cycle is level.
Leveling
Feet
HOW TO ADJUST THE REED SWITCH
If the console does not
display correct feed-
back, the reed switch
should be adjusted.
First, use a small flat
screwdriver to careful-
ly pry off the left Side
Shield Cover (14).
Next, rotate the left
Pedal Guard (8) and
pull it away from the Left Side Shield (4).
Next, locate the
Reed Switch
(49). Turn the
Left Crank Arm
(15) until the
Magnet (23) is
aligned with the
Reed Switch.
Loosen, but do
not remove, the
indicated M4 x
16mm Screw
(54). Slide the
Reed Switch
slightly closer
to or away from the Magnet. Then, retighten the
Screw. Turn the Left Crank Arm for a moment. Repeat
until the console displays correct feedback. When the
Reed Switch is correctly adjusted, reattach the left
Pedal Guard (8) and the left Side Shield Cover (14).
17
4
15
49
23
54
8
14