Technical Specifications - HP ProLiant BL460c Quickspecs

Server blade
Hide thumbs Also See for ProLiant BL460c:
Table of Contents

Advertisement

QuickSpecs

Technical Specifications

System Unit
Dimensions (H x W x D)
(with bezel)
Weight
(approximate)
Power Specifications
System Inlet Temperature Operating
Relative Humidity
(non-condensing)
Altitude
Acoustic Noise
DA - 12518
Worldwide QuickSpecs — Version 35 — 4.27.2009
7.154 x 2.19 x 20.058 in (18.17 x 5.56 x 50.95 cm)
Maximum
(all hard drives and
processors installed)
Minimum
(one hard drive and
processor installed)
For power specifications including Input Requirements, BTU Rating, and
Power Supply Output, please see the HP BladeSystem c-Class Enclosures
QuickSpecs located at URL:
HP BladeSystem c3000 Enclosure QuickSpecs:
http://h18000.www1.hp.com/products/quickspecs/12790_div/
12790_div.html
HP BladeSystem c7000 Enclosure QuickSpecs:
http://h18000.www1.hp.com/products/quickspecs/12810_div/
12810_div.html
To review typical system power ratings use the HP BladeSystem Power Sizer
which is available via the online tool located at URL:
http://www.hp.com/go/bladesystem/powercalculator
Non-operating
Operating
Non-operating
Operating
Non-operating
For acoustic noise specifications, please see the HP BladeSystem c-Class
Enclosures QuickSpecs located at URL:
HP BladeSystem c3000 Enclosure QuickSpecs:
http://h18000.www1.hp.com/products/quickspecs/12790_div/
HP ProLiant BL460c Server Blade
14.20 lb (6.44 kg)
10.75 lb (4.87 kg)
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-condensing.
5 to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature, non-
condensing.
3050 m (10,000 ft). This value may be limited
by the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500
ft/min).
Page 29