HP ProLiant BL460c Quickspecs page 17

Server blade
Hide thumbs Also See for ProLiant BL460c:
Table of Contents

Advertisement

QuickSpecs
Configuration Information - Factory Integrated Models
Memory
Step 3: Choose Additional Factory Integratable Options (one of the following from each
unless otherwise noted):
Hard Drive Backplane HP ProLiant BL460c Hard Disk Drive Backplane, FIO
Controller Cache
Intel® Xeon® processor X5270 (3.50 GHz, 1333 FSB, 80W)
NOTE: If 2 processors are desired, select one 492309-L21 and one 492309-B21.
Intel® Xeon® processor X5260 (3.33 GHz, 1333 FSB, 80 W) Option Kit, FIO Base
NOTE: If 2 processors are desired, select one 461623-L21 and one 461623-B21.
Intel® Xeon® processor L5240 (3.00 GHz, 1333 FSB, 40 W, LV) Option Kit, FIO
Base
NOTE: If 2 processors are desired, select one 461624-L21 and one 461624-B21
Intel® Xeon® processor E5205 (1.86 GHz, 1333 FSB, 65 W) Option Kit, FIO Base
NOTE: If 2 processors are desired, select one 461625-L21and one 461625-B21.
1 GB FBD PC2-5300 (2 x 512 MB) Kit
2 GB FBD PC2-5300 (2 x 1 GB LP) Kit
2 GB FBD PC2-5300 (2 x 1 GB) Kit
4 GB FBD PC2-5300 (2 x 2 GB LP) Kit
4 GB FBD PC2-5300 (2 x 2 GB) Kit
8 GB FBD PC2-5300 (2 x 4 GB) Kit
8 GB FBD PC2-5300 (2 x 4 GB LP) Kit
16 GB FBD PC2-5300 (2 x 8 GB) Kit
64 GB FBD PC2-5300 (8 x 8 GB) Kit
NOTE: Memory Option Kits described as LP include Low Power DIMMs. For more
information on ProLiant Energy Efficient Features, see:
http://h18004.www1.hp.com/products/servers/platforms/energyefficient/
NOTE: Must be installed in pairs
NOTE: 64GB of memory is supported with 80W processors and below. 64GB of
memory is Not supported with 120W processors.
NOTE: Up to three 16 GB (2 x 8 GB) memory option kits or 48 GB of memory is
supported with 120W processors.
NOTE: Includes USB connector.
NOTE: The Hard Drive Backplane is required for all blades that support hard disk
drives or require the internal USB 2.0 connector for security key devices, licensing or
VMware ESX Server 3i.
64 MB Cache - FIO Only
NOTE: Integrated HP Smart Array E200i RAID controller supporting RAID 0/1
Controller cache module selection is required for all blades that support hard disk
drives. Select either the standard 64 MB module above or the optional 128 MB
module below.
NOTE: This option is not required when configuring a Drive-less Model.
128 MB Battery-Backed Cache Enabler
NOTE: Supports the HP Smart Array E200i Controller.
NOTE: This option is not required when configuring a Drive-less Model.
DA - 12518
Worldwide QuickSpecs — Version 35 — 4.27.2009
HP ProLiant BL460c Server Blade
492309-L21
461623-L21
461624-L21
461625-L21
397409-B21
461826-B21
397411-B21
461828-B21
397413-B21
397415-B21
466440-B21
413015-B21
495604-B21
447711-B21
405102-B21
351580-B21
Page 17

Advertisement

Table of Contents
loading

Table of Contents