Unscrew the nozzle located inside the gas fitting
using a 7 mm [ socket wrench].
Replace the nozzle using the conversion set
supplied with the range or by a Bertazzoni
authorized parts warehouse. Each nozzle has a
number indicating its flow diameter printed on
the body. Consult the table on page 20 for
matching nozzles to burners.
Do not need air adjustment on the oven burner.
STEP 4: BROILER BURNER
Loosen the screw and pull out the burner from its
support.
ATTENTION: pay extra attention to avoid damage
to the igniter and thermocouple.
Using a 7 mm [name of the tool] unscrew the
nozzle. Replace the nozzle using the conversion
set supplied with the range or by a Bertazzoni
authorized parts warehouse. Each nozzle has a
number indicating its flow diameter printed on
the body. Consult the table on page 20 for
matching nozzles to burners.
Adjust the gap X by setting it to fully open
position.
17