PRESSURE REGULATOR  
Since service pressure may fluctuate with local 
demand, every gas cooking appliance must be 
equipped with a pressure regulator on the 
incoming service line for safe and efficient 
operation. 
The pressure regulator shipped with the 
appliance has has two female threads ½" NPT. 
The regulator shall be installed properly in order 
to be accessible when the appliance is installed in 
its final position.  
 
Manifold pressure should be checked with a 
manometer and comply with the values indicated 
below: 
Natural gas  4.0" W.c.P.  
LP/Propane  11.0" W.C.P.  
Incoming line pressure upstream from the 
regulator must be 1" W.c.P. higher than the 
manifold pressure in order to check the 
regulator.  
The regulator used on this range can withstand a 
maximum input pressure of 1/2 PSI (14.0" W.c.P.) 
If the line pressure exceeds that amount, a step‐
down regulator is required. 
The  appliance,  its  individual  shut‐off  valve,  and 
the  pressure  regulator  must  be  disconnected 
from  the  gas  line  during  any  pressure  testing  of 
that  system  at  pressures  in  excess  of  1/2  psig 
(3.45 kPa). 
The  individuaL  manual  shut‐off  valve  must  be  in 
the  OFF  position  during  any  pressure  testing  of 
the  gas  supply  piping  system  at  test  pressures 
equal to or less than ½ psig (3.45 kPa). 
 