The outcome of the configuration update will be displayed. If an error occurred with
the TFTP address or file pathname, the message will indicate a time-out condition. If
an error was encountered in the configuration file, the display includes the command
line number and the erroneous entry.
The EEPROM configuration is updated immediately, but some changes may not take
effect until the next reboot. The display will indicate if a reboot is required.

5.10 Rebooting the Hub

The Reboot operation reboots the ESP-2 serial hub. A reboot is usually required for
the following operations to take effect:
Changing network address values
Changing the RS-485 transfer mode
Changing any configurable features
Updating FLASH
To reboot:
1.
From the Top Menu, enter
2.
From the Server Configuration menu, enter
You may also reboot the ESP-2 hub using the web interface (see Reinitializing the
Hub on page 30) or the RESET button on the front panel (see Resetting on page 9).

5.11 Reinitializing the Hub

The Reinitialize command resets all configurable values to their factory defaults,
including the IP address and password.
To reinitialize:
1.
From the Top Menu, enter
2.
From the Server Configuration menu, enter
You may also reinitialize the ESP-2 serial hub using the web interface (see
Reinitializing the Hub on page 30) or the INIT button on the front panel (see
Reinitializing on page 9).

5.12 Displaying General Statistics

The General Statistics display includes the items described in Table 17 on page 28.
All values are cumulative since the ESP-2 serial hub was last reset.
To display general statistics:
1.
From the Top Menu, enter
2.
From the Status Menu, enter

5.13 Displaying Port Statistics

The Port Statistics display includes the information described in Table 18 on page 28
for each port. All values are cumulative since the ESP-2 serial hub was last reset.
38
to select Server Configuration.
0
6
to select Server Configuration.
0
to select Re-Initialize (factory defaults).
7
to select Status.
3
to select General statistics.
1
Equinox ESP-2 MI Serial Hub Installation and User Guide
to select Reboot.

Hide quick links: