Equinox Systems ESP-2 MI Installation And User Manual page 25

Serial hub
Hide thumbs Also See for ESP-2 MI:
Table of Contents

Advertisement

Table 14 lists the serial port attributes with their valid and default values.
Table 14: Serial Port Valid and Default Values
Attribute
Baud rate
Bits per character
(size)
Parity
Stop bits
Flow control
Equinox ESP-2 MI Serial Hub Installation and User Guide
Valid and Default Values
Valid values: 50, 75, 110, 134, 150, 200, 300, 600, 1200, 2400, 4800,
9600, 19200, 38400, 57600, 76800, 115200 and 230400
Default value: 19200
Valid values: 5, 6, 7 and 8
Default value: 8
Valid values: None, Even, Odd, Mark and Space
Default value: None
Valid values: 1 and 2
Default value: 1
Valid values: None, XON/XOFF and RTS/CTS
Default value: None
Flow control settings are full duplex. RTS/CTS flow control is valid only
on RS-232 ports.