Venting Requirements - KitchenAid 30" (76.2 CM) SLIDE-OUT RANGE HOOD Installation Instructions And Use & Care Manual

30" (76.2 cm) and 36" (91.4 cm) slide-out range hood
Table of Contents

Advertisement

Available languages

Available languages

Product Dimensions
6" (15.2 cm)
front edge to
damper centerline
30" (76.2 cm) - 30" (76.2 cm) model
36" (91.4 cm) - 36" (91.4 cm) model
Cabinet Dimensions
30" (76.2 cm) or
36" (91.4 cm) min.
cabinet opening width
24" (61 cm) min.
32" (81 cm)
suggested max.
bottom of cabinet
to cooking surface
15" (38.1 cm)
min. clearance
upper cabinet
to countertop
36" (91.4 cm)
base cabinet
height
" (23.0 cm)
6" (15.2 cm)
15" (38.1 cm)
min. upper
cabinet height
12" (30.5 cm)
cabinet depth
21" (53.3 cm)
9
" (24.9 cm)
11
" (28.1 cm)
6 " (17.5 cm) with
screen extended

Venting Requirements

(vented models only)
Vent system must terminate to the outside, except for non-
vented (recirculating) installations.
Do not terminate the vent system in an attic or other enclosed
area.
Do not use a 4" (10.2 cm) laundry-type wall cap.
Use metal vent only. A rigid metal vent is recommended.
Plastic or metal foil vent is not recommended.
The length of the vent system and number of elbows should
be kept to a minimum to provide efficient performance.
For the most efficient and quiet operation:
Use no more than three 90° elbows.
Make sure there is a minimum of 24" (61.0 cm) of straight
vent between the elbows if more than 1 elbow is used.
Do not install 2 elbows together.
The vent system must have a damper. If the roof or wall cap
has a damper, do not use the damper supplied with the range
hood.
Use clamps to seal all joints in the vent system.
Use caulking to seal exterior wall or roof opening around the
cap.
The size of the vent should be uniform.
2 " (7.0 cm)
" - 1 " (2.4 cm - 4.4 cm)
trim extension
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents