Henny Penny PFE-590 Technical Manual page 11

Pressure fryer-electric
Hide thumbs Also See for HENNY PENNY PFE-590:
Table of Contents

Advertisement

Problem
Pressure does not
build
1103
Cause
PRESSURE SECTION (Continued)
Not enough product in fryer
or product not fresh
Metal shipping spacer not
removed from dead weight
Lid open or not latched
Solenoid valve leaking or
not closing
Dead weight valve leaking
Pressure not programmed
Lid gasket leaking
Safety relief valve leaking
• Pressure pad broken or crushed
Model 590/592
Correction
Place proper quantity of
fresh product within
frypot to generate steam
Remove shipping spacer.
See Unpacking Section of
Operator 's Manual
Close and latch lid
Check or clean solenoid
valve per maintenance
section on the solenoid valve
Repair per maintenance section on
deadweight valve
Check programming
Reverse gasket or lid needs
adjusted; see Reversing the Lid
Gasket and Lid Adjustment
Sections
Check and replace if necessary per
maintenance section on the safety
relief valve
• Replace pressure pads
1-7