7) Pour the cleaning solution into the water tank.
8) Move the control switch on the control box to the "WASH" position.
9) Replace the insulation panel and the front panel in their correct positions.
10) Turn on the power supply to start the washing process.
11) Turn off the power supply after 30 minutes.
12) Remove the front panel.
13) Disconnect one end of the pump tubing to drain the water tank. After the water tank has
drained, reconnect the pump tubing.
14) Move the control switch to the "ICE" position.
15) Replace the front panel in its correct position.
16) Turn on the power supply to fill the water tank with water.
17) Turn off the power supply after 3 minutes.
18) Remove the front panel.
19) Move the control switch to the "WASH" position.
20) Replace the front panel in its correct position.
21) Turn on the power supply to rinse off the cleaning solution.
22) Turn off the power supply after 5 minutes.
23) Remove the front panel.
24) Disconnect one end of the pump tubing to drain the water tank. After the water tank has
drained, reconnect the pump tubing.
25) Repeat steps 14 through 24 three more times to rinse thoroughly.
Note: If you do not sanitize the icemaker, go to step 10 in "2. Sanitizing Procedure."

2. Sanitizing Procedure - Following Cleaning Procedure

1) Dilute a 5.25% sodium hypochlorite solution (chlorine bleach) with warm water. (Add
1.5 fl. oz. (44 ml) of sanitizer to 3 gal. (11 l) of water.)
2) Remove the insulation panel.
3) Pour the sanitizing solution into the water tank.
4) Replace the insulation panel and the front panel in their correct positions.
Note: Make sure the control switch is in the "WASH" position.
5) Turn on the power supply to start the sanitizing process.
6) Turn off the power supply after 15 minutes.
7) Remove the front panel.
8) Disconnect one end of the pump tubing to drain the water tank. After the water tank has
drained, reconnect the pump tubing.
9) Repeat steps 14 through 24 in "1. Cleaning Procedure" two times to rinse thoroughly.
10) Move the control switch to the "ICE" position.
11) Replace the front panel and the base cover in their correct positions.