Hoshizaki KM-901MAH50 Instruction Manual page 19

Modular crescent cuber
Table of Contents

Advertisement

1. Icemaker
• Icemaker water supply inlet is 1/2" female pipe thread (FPT). A minimum of 3/8" OD
copper tubing is recommended for the icemaker water supply line.
• An icemaker water supply line shut-off valve and drain valve should be installed.
• Icemaker drain outlet is 3/4" FPT. A minimum of 3/4" OD hard pipe is recommended for
the icemaker drain line. Condensation drain outlet is 3/8" OD tube. The condensation
drain line can be connected to the icemaker drain line or can be run separately.
Icemaker
Water Supply
Inlet
1/2" FPT
Bin
Fig. 12
Icemaker
KM-901MAH50 and KM-901MRH50
Icemaker Water Supply Line
Drain Valve
Icemaker
Drain Outlet
3/4" FPT
Bin Drain Outlet
3/4" FPT
Separate piping to approved drain.
Leave a two-inch (5 cm) vertical air
gap between the end of each pipe
and the drain.
19
Icemaker Water Supply Line
Shut-Off Valve
Condensation
Drain Outlet
3/8" OD Tube
Two-inch
(5 cm) air
gap
Floor Drain