Cleaning; Conventional Cleaning - Henny Penny CLIMAPLUS LCS Applications Manual

Applications manual and cooking guide
Table of Contents

Advertisement

+CLEAN
PROG
START
OR

Cleaning

Your ClimaPlus
®
Combi MUST be cleaned at least once a day to ensure
proper sanitation and continued trouble-free operation. Daily cleaning can be
accomplished in two ways:
Conventionally using Moist Heat mode and/or pre-set cleaning program.
With the CleanJet automated cleaning feature.

Conventional Cleaning

All ClimaPlus Combis are equipped with a preset cleaning program and a
built-in retractable hand shower for rinsing. The unit uses its own built-in
water supply, plus heat and steam from Moist Heat mode operation to do
most of the work.
For best results with conventional cleaning, use Henny Penny Oven and Grill
Cleaner and follow the procedures outlined below:
1. Leave hinged racks or mobile oven racks and grids. Stainless steel containers
may also be left in the cooking cabinet.
2. Allow cooking cabinet to cool down below 130°F (55°C).
3. Spray all interior cabinet surfaces (even behind the pivoted air baffle) as well
as oven rack, grids and pans thoroughly with Henny Penny Oven and Grill
Cleaner. (Goggles and gloves should be worn when using chemicals.)
To initiate factory pre-set cleaning program (about 40 minutes)
NOTE: If you do not wish to use pre-set cleaning program, skip steps 4-6.
4. Press IQT key
5. Select "*CLEAN" using central dial.
6. Press PROG/START and skip steps 7-9.
7. Let cleaner act for approximately 20 minutes.
8. Select Moist Heat mode.
9. Select TIMER and set for 15 minutes.
10. Repeat process for heavily soiled cabinet.
11. Rinse thoroughly with built-in hand shower.
NOTE: To activate the hand shower water flow, pull hose to full extension and
release to rest position. Press spray gun button.
54

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents