2-3. ELECTRICAL CONNECTION

2-4. ELECTRICAL DATA TABLE

2-2
The island warmer is available from the factory wired
for 120/208-240 volts (domestic), or 230 volt and 400
volt (international), single or three phase, 3 or 4 wire
plus ground (includes neutral). The proper power
service cable is provided with domestic units, but not
on international units.
This unit must be adequately and safely grounded. Refer
to local electrical codes for correct grounding procedures.
If unit is not adequately grounded, electrical shock could
result.
A separate disconnect switch with proper capacity fuses or
breakers must be installed at a convenient location between
the unit and the power source.
Model
Volts Phase Watts Amps Wires
HMI-103
120/208
HMI-103
120/208
HMI-103
120/240
HMI-103
120/240
HMI-105
120/208
HMI-105
120/208
HMI-105
120/240
HMI-105
120/240
HMI-103
230
HMI-105
400
Model HMI-103/105
1
2400
11.0
3+G
3
2400
8.0
4+G
1
2600
11.0
3+G
3
2600
7.5
4+G
1
3900
18.0
3+G
3
3900
13.0
4+G
1
4200
17.5
3+G
3
4200
12.0
4+G
1
2600
11.3
4+G
3
4200
7.8
4+G