(Example: ./ipmitool raw 0xc 1 1 3 10 106 42 120 to set IP address
of BMC LAN port as 10.106.42.120)
Table 2-1. The D4 Token Table
Token
Setup option
Embedded
002D
NIC1
Embedded
002E
NIC1
N/A
0051
N/A
0052
N/A
0053
N/A
0054
N/A
005C
N/A
005D
Embedded
006E
NIC1
Video
0087
Enumeration
Description
Enables the system's primary embedded network
interface controller (full-function), including its
PXE boot-ROM.
Disables the system's primary embedded network
interface controller.
For the next system boot, set the IPL priority to: USB
storage, hard disk, CD/DVD-ROM, RAID, Network (if
the devices are available)
For the next system boot, set the IPL priority to: hard
disk then option ROMs (if the devices are available)
For the next system boot, set the IPL priority to:
Network, hard disk, RAID,USB storage, CD/DVD-
ROM (if the devices are available)
For the next system boot, set the IPL priority to:
CD/DVD-ROM, USB Storage, hard disk, RAID,
Network (if the devices are available)
Enables the BIOS remote update on the next reboot,
to search for an operating-system initiated
BIOS update image.
Disables the BIOS remote update on the next reboot,
to search for an operating-system initiated
BIOS update image.
Enable the system's primary embedded network
interface controller, but don't enable the NIC's
associated PXE or RPL boot-ROM.
The onboard video controller is used for boot-time
messages.
Installing System Components | 99