Contents Blue Seal Gas Target Top Range / Electric Ovens GE570 Gas Target Top Range / Electric Static Oven. GE576 Gas Target Top Range / Electric Convection Oven. Introduction ....................2 Specification ....................3 Model Numbers Covered in this Specification...
Introduction We are confident that you will be delighted with your BLUE SEAL Gas Target Top Range / Electric Ovens, and it will become a most valued appliance in your commercial kitchen. To ensure you receive the utmost benefit from your new Blue Seal appliance, there are two important things you can do.
Specifications Model Numbers Covered in this Specification GE570 Gas Target Top Range / Electric Static Oven - 900mm. GE576 Gas Target Top Range / Electric Convection Oven - 900mm. General A commercial heavy duty, gas fired Target Top having a high output, two stage double-ring iron cast burner offering accurate temperature control and infinitely variable heat with the heat radiating out from the centre of the Target Top.
Blue Seal Target Top Range / Electric Ovens are designed to provide years of satisfactory service, and correct installation is essential to achieve the best performance, efficiency and trouble-free operation.
Installation Clearances NOTE: Only non-combustible materials can be used in close proximity to this appliance. Combustible Surface Non Combustible Surface Left / Right hand side 50mm Rear 50mm * Side clearances can be 50mm when the adjacent surface is at least 100mm below the cooking surface.
Installation NOTE: • The burner operating pressure is to be measured at the manifold test point with the main burner operating at the 'High Flame' setting. • NAT, LPG & Butane Only - The operating pressure is ex-factory set and is not to be adjusted, apart from when converting between gasses, if required.
Page 11
Installation AUTIO N Changing the supply from 3 phase to single phase will increase the electrical current loading on the supply cable. Ensure that the supply cable used is of a sufficient size current loading, refer 'Electrical Supply Requirements' table overleaf. Connect neutral and earth conductors to neutral stud and earth stud respectively.
/ operator. Blue Seal appliances have been designed to provide simplicity of operation and 100% safety protection. Improper operation is therefore almost impossible, however bad operation practices can reduce the life of the appliance and produce a poor quality product.
Operation Lighting the Pilot Burner (Target Top) Remove centre casting with the casting removal tool. Depress the control knob and rotate anti-clockwise to the ‘PILOT’ position. With the control knob depressed, manually light the pilot burner located in front of the main burner. Hold in the control knob for approximately 10 to 15 seconds, then release.
The oven is fitted with top and bottom elements. The thermostat maintains the overall oven temperature. The top element is further controlled by the oven top heat control. Convection Ovens (GE570 / GE576) are fitted with a circulation fan. NOTE: The Thermostat on the static oven provides overall control of the temperature within the oven by controlling both elements, where as the Oven Top Heat Control provides a means of balancing the distribution of heat between the top and bottom of the oven.
Cleaning and Maintenance AUTIO N Always turn ‘Off’ the electrical and gas supply before cleaning. This appliance is not water proof. Do not use water jet spray to clean interior or exterior of this appliance. General Clean the Target Top / Range regularly. A clean appliance looks better, will last longer and will perform better.
Cleaning and Maintenance Target Top a. This should be kept clean of any build up of spillage’s of food. Provided the cast iron work surface is regularly used it will maintain itself in good condition with no special cleaning requirements being necessary. b.
Fault Finding This section provides an easy reference guide to the more common problems that may occur during the operation of your appliance. The fault finding guide in this section is intended to help you correct, or at least accurately diagnose problems with your equipment. Although this section covers the most common problems reported, you may encounter a problem not covered in this section.
Gas Conversion and Specifications Conversion Procedure AUTIO N Ensure that the appliance is isolated from the gas supply before commencing servicing. NOTE: • These conversions should only be carried out by qualified persons. All connections must be checked for leaks before re-commissioning the appliance. •...
Page 23
Gas Conversion and Specifications Pilot Burner Pilot Burner Main Burner To remove the pilot burner, disconnect the gas Injectors supply tube from the base of the pilot burner. Remove the bolt securing the retaining plate holding the pilot burner and thermo couple to the Gas Supply mounting bracket.
Gas Conversion and Specifications Gas Regulator - NAT Gas / LPG / Butane Only. NOTE, Pin rotated for Natural Gas NOTE, Pin rotated for LPG Fig 16 NOTE: The regulator supplied is convertible between Natural Gas and LP Gas, but it’s outlet pressure is fixed ex-factory and is NOT to be adjusted.
Page 25
Gas Conversion and Specifications Gas Type Identification Label On completion of the gas conversion, replace gas type identification label, located:- - At the rear of the unit, above the gas connection. - Beside the Rating Plate. Commissioning Before leaving the converted installation; Check all gas connections for leakages using soapy water or other gas detecting equipment.
Gas Conversion and Specifications Gas Specifications Natural Gas LP Gas Butane Town Gas (**) Main Burner Injector Ø 1.70 mm Ø 1.10 mm Ø 1.00 mm Ø 4.20 mm (Inner Ring) Main Burner Injector Ø 2.60 mm Ø 1.55 mm Ø...
Replacement Parts List Replacement Parts List IMPORTANT: Only genuine authorized replacement parts should be used for the servicing and repair of this appliance. The instructions supplied with the parts should be followed when replacing components. For further information and servicing instructions, contact your nearest authorized service branch (contact details are as shown on the reverse of the front cover of this manual).
Page 28
Australia / New Zealand Only Gas Type to Convert to Model Nat. Gas Butane Town Gas GE570 / GE576 231972 231971 231973 N/A (*) NOTE; (*) Town Gas Option is only available with specific ex-factory built Town Gas models, which can also be converted to any other gas.