Chimney Requirements - Outdoor Lifestyles CASTLEWOOD 42 Owner's Manual

Outdoor woodburning installation and operation
Hide thumbs Also See for CASTLEWOOD 42:
Table of Contents

Advertisement

E. Chimney Requirements
When planning your fireplace location, the chimney construc-
tion and necessary clearances must be considered. The fire-
place system and chimney components have been tested to
provide flexibility in construction. The following figures are
the minimum distances from the base of the fireplace.
Minimum overall straight height is 10 ft If the fireplace is
freestanding and a minimum of 10 ft from a combustible
structure. See Figure 3.2.
Chimney must extend 2 ft (.6 m) above any portion of
the roof within 10 ft (3048 mm) of the chimney. Refer to
Figure 6.2.
Minimum heightwith offset/return
Maximum height
Maximum chimney length between an offset
and return
Maximum distance between chimney
stabilizers
Double offset/return minimum height
Maximum unsupported chimney length
between the offset and return
• Maximum unsupported chimney height above
the fireplace
Minimum overall straight height if fireplace is
freestanding
* Transition section standard with unit and 1 foot section
required in addtion as minimum or SLA10 (for Canada)
Outdoor Lifestyles by Hearth & Home Technologies Inc. • 4070-300 Rev C • 4/11
ft
m
16
4.88
90
27.43
20
6.1
35
10.67
24
7.32
6
1.83
35
10.67
6.33
1.93
91/2 ft
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Outdoor woodburning castlewood 42

Table of Contents