Installation of Fireplace

A. Secure the Fireplace
Position the Fireplace
This fireplace may be placed on either a combustible
or noncombustible continouous flat surface. Follow the
instructions for framing in Section 3.D. Slide the fireplace
into position. Be sure to provide the minimum air clear-
ance at the sides and back of the fireplace assembly. See
Section 3.B.
WARNING
FIre Risk!
Prevent contact with sagging, loose
insulation.
Do NOT instal against vapor barriers or
exposed
insulation.
Cooling Air Hoods must be installed if
instaling
on a combustible surface.
Level the Fireplace
Level the fireplace side-to-side and front-to-back. Shim with
noncombustible material, such as sheet metal, as neces-
sary. Secure the fireplace (using the nailing flanges located
on either side of the fireplace) to the vertical framing.
Note: When elevating the fireplace above the hearth
extension the front of the elevated platform must be
protected with a protective metal hearth strip.
Important: To ensure proper fit of the glass doors, check
the fireplace opening for square. Measure diagonal
distances of the opening to make sure they are equal.
If they are not, continue to shim the fireplace until those
diagonals are equal.
Top piece must overlap
Raised Platform
2 in.
(51 mm)
2 in.
(51 mm)
Figure 4.2
Protect the Front of an Elevated Platform
12
Outdoor Lifestyles by Hearth & Home Technologies Inc. • 4070-300 Rev C • 4/11
bottom piece
1 in. (25 mm) min.
overlap
Floor
Place the Protective Metal Hearth Strips
Protective metal strips are placed 2 in. (51 mm) under the
front of the fireplace and must extend beyond the front
and sides of fireplace opening by 2 in. (51 mm).
Figure 4.1
Position the Protective Metal Hearth Strips
Included with your fireplace you will find two metal hearth strips
measuring approximately 26 in. x 4 in. (660 mm x 102 mm).
These strips are used to provide added protection where the
fireplace and the hearth extension meet when installed on
a combustible service.
Slide each metal strip 2 in. (51 mm) under the front edge of
the fireplace. The individual pieces must overlap each other
by 1 in. (25 mm) minimum in the middle of the fireplace to
provide continuous coverage of the floor. See Figure 4.1.
These metal strips should extend from the front and sides of
the fireplace opening by 2 in. (51 mm).
WARNING
Fire Risk!
Metal hearth strips MUST be installed.
Sparks or embers may ignite flooring.
1 in. (25 mm)
overlap