Clear Space Near The Fireplace; Firescreen; Glass Doors - Outdoor Lifestyles CASTLEWOOD 42 Owner's Manual

Outdoor woodburning installation and operation
Hide thumbs Also See for CASTLEWOOD 42:
Table of Contents

Advertisement

C. Clear Space Near the Fireplace
Combustible materials must not be stored on the hearth ex-
tension. Outdoor room furnishings such as chairs or other
combustibles must be at least 4 ft (1.22 m) from the open
front of the fi replace.
THERE IS NOT A FLUE DAMPER, THEREFORE UNIT
CANNOT BE INSTALLED INDOORS.
28
Outdoor Lifestyles by Hearth & Home Technologies Inc. • 4070-300 Rev C • 4/11
D. Firescreen
A fi rescreen is always provided to control sparks. It must be
closed whenever the fi replace is in use. Glass doors or fi re-
screens must not be used to hold burning material inside the
fi replace. Only those glass doors specifi cally tested and list-
ed for use with the specifi c fi replace model should be used.
Screens should be closed when the glass doors are closed.
WARNING
Fire Risk
Close fi rescreen when burning fi replace.
Do not use fi rescreen or glass doors to
hold burning material in fi replace.
Firescreen controls sparks.
Glass may break or burning material may
roll out.
E. Glass Doors
Most effi cient fi replace operation using glass doors is with
the doors open. When the doors are open the screen must
be closed. Only Hearth & Home Technologies glass doors
may be used. See Figure 10.1 for proper glass door opera-
tion.
FULLY OPEN
CORRECT
FULLY CLOSED
CORRECT
Figure 10.1 Proper Operating Positions of Bi-fold Doors
WARNING
Fire Risk
Smoke Risk
Doors must be fully opened or fully closed
when operating fi replace.
Partially opened doors may draw fl ame, smoke
or heat from fi replace.
PARTLY OPEN
INCORRECT
PARTLY CLOSED
INCORRECT

Advertisement

Table of Contents
loading

This manual is also suitable for:

Outdoor woodburning castlewood 42

Table of Contents