5

Chimney Assembly

A. Chimney Requirements
Vertical distances are measured from the base of the fire-
place.
Minimum overall straight height is 10 ft. if the fireplace is
freestanding and a minimum of 10 ft from a combustible
structure.
Chimney must extend 2 ft (.6 m) above any portion of the
roof within 10 ft (3 m) of the chimney. To determine the
chimney components needed to complete your particular
installation, follow the steps below:
Determine the total vertical height of the fireplace
installation. This dimension is measured from the base of
the fireplace assembly to the point where the smoke exits
the termination cap.
Subtract the effective height of the fireplace assembly from
the overall height of the fireplace installation (measured
from the base of the fireplace to the bottom of the
termination cap).
Refer to Table 5.1 to determine what components must
be selected to complete the fireplace installation.
Determine the number of ceiling firestops, stabilizers,
roof flashing, etc. required to complete the fireplace
installation.
Minimum heightwith offset/return
Maximum height
Maximum chimney length between an offset
and return
Maximum distance between chimney
stabilizers
Double offset/return minimum height
Maximum unsupported chimney length
between the offset and return
• Maximum unsupported chimney height above
the fireplace
Minimum overall straight height if fireplace is
freestanding
* Transition section standard with unit and 1 foot section
required in addtion as minimum
Note: A maximum of two pairs of offsets and returns may
be used.
14
Outdoor Lifestyles by Hearth & Home Technologies Inc. • 4070-300 Rev C • 4/11
ft
m
16
4.88
90
27.43
20
6.1
35
10.67
24
7.32
6
1.83
35
10.67
6.33
1.93
.
WARNING
Fire Risk
Must maintain 2 in. (51 mm) air
clearance to insulation and other
combustible materials.
Warning: DO NOT PACK REQUIRED
AIR SPACES WITH INSULATION OR
OTHER MATERIALS.
CAUTION
Do NOT connect this fireplace to a chimney flue
servicing another appliance.
Do NOT connect to any air distribution duct or
system.
Table 5.1
HEIGHT OF CHIMNEY
COMPONENTS
US
Chimney Stabilizer
SL11
Ceiling Firestops
FS538
FS540
Offsets/Returns
SL1130
Chimney Sections*
SL1106
SL1112
SL1118
SL1136
SL1148
n/a
* Dimensions reflect effective height.
in.
Canada ONLY
SL4
4-3/4
FS538
0
FS540
0
SL430
14-1/2
SL406
4-3/4
SL412
10-3/4
SL418
16-3/4
SL436
34-3/4
SL448
46-3/4
1187
SLA10
16-3/4
mm
121
0
0
368
121
273
425
883
425

Advertisement

Table of Contents
loading

This manual is also suitable for:

Outdoor woodburning castlewood 42

Table of Contents