Maintenance Task List; Chimney Fire - Outdoor Lifestyles CASTLEWOOD 42 Owner's Manual

Outdoor woodburning installation and operation
Hide thumbs Also See for CASTLEWOOD 42:
Table of Contents

Advertisement

CAUTION
Handle glass assembly with care.
When cleaning glass door:
Avoid striking, scratching or slamming
glass.
Do NOT use abrasive cleaners.
Use a hard water deposit glass cleaner on
white film.
Do NOT clean glass when it is hot.
WARNING
Fire Risk
Do not use chimney cleaners or flame
colorants in your fireplace.
Will corrode chimney.
D. Maintenance Task List
Inspect
Screens
1 Assess condition of screen and replace as necessary. Screens are required.
2 Verify maintenance of proper clearance to combustible household objects.
Glass Doors
1 Inspect glass panels for cracks. Replace if this condition is present.
2 Confirm there is no damage to glass or glass frame. Replace as necessary.
3 Clean glass using a non-abrasive cleaner such as Brasso©.
Circulation Compartment
1 Remove any foreign objects.
2 Verify unobstructed air circulation.
Firebox
1 Inspect condition of refractory. Replace if crumbly, deteriorated, or if cracks exceed 1/4 in. (6
Chimney
1 Inspect for blockage or obstruction such as bird nests, leaves, etc.
2 Confirm that termination cap remains clear and unobstructed by plants, etc.
3 Verify that termination cap clearance to subsequent construction (building additions) has been
4 Inspect for corrosion or separation.
5 Verify weather stripping, sealing and flashing remain intact.
6 Inspect for creosote and remove as needed. (See Sections 10 and 11)
Grate
1 If grate burns out, it should be replaced only with the grate specified on the rating plate and in
E. Chimney Fire
In the event of a chimney fire:
Have the chimney and adjacent structure inspected by
qualified professionals. Hearth & Home Technologies
recommends that NFI or CSIA certified professionals, or
technicians under the direction of certified professionals,
conduct a minimum of an NFPA 211 Level 2 inspection
of the chimney.
Outdoor Lifestyles by Hearth & Home Technologies Inc. • 4070-300 Rev C • 4/11
mm).
maintained.
the replacement parts list for this fireplace.
Asphyxiation Risk
Fire Risk
Annual inspection by qualified technician
recommended.
Check:
Clean:
Maintenance Tasks
Replace components of the chimney and fireplace as
specified by the professionals.
Ensure all joints are properly engaged and the chimney
is properly secured.
A chimney fire can permanently damage your chimney sys-
tem. Failure to replace damaged components and make
proper repairs creates risk of fire.
WARNING
Condition of doors, surrounds and fronts
Condition of glass and glass assembly
Obstructions of combustion and ventilation
air
Gas connections and fittings (if present)
Obstructions of termination cap
Refractory panels
Glass
Air passageways, grilles
33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Outdoor woodburning castlewood 42

Table of Contents