Installation Of Molded Brick Panel; Install Hearth Molded Brick Panel; Install Back Molded Brick Panel; Install Side Molded Brick Panel - Outdoor Lifestyles CASTLEWOOD 42 Owner's Manual

Outdoor woodburning installation and operation
Hide thumbs Also See for CASTLEWOOD 42:
Table of Contents

Advertisement

7

Installation of Molded Brick Panel

A. Install Hearth Molded Brick Panel
1. Put a level on fireplace to verify it is level side to side
and front to back.
2. While the hearth is removed from the fireplace , measure
all 4 corrners to determine the variance from corner to
corner. See Figure 7.1.
3. Shim the low corners of the hearth refractory by installing
the metal pieces provided on the fireplace bottom. See
Figure 7.2.
4. Put a level on the top flange of the refractory and shim as
necessary from side to side or front to back. See Figure
7.3.
Note: The top flange of the hearth should be level to allow
the sides and back to be installed with minimal gaps. The
hearth slopes towards the front of the unit approximately
1/4".
Figure 7.1.
Figure 7.2.
Figure 7.3.
Outdoor Lifestyles by Hearth & Home Technologies Inc. • 4070-300 Rev C • 4/11
B. Install Back Molded Brick Panel
Refer to Figure 7.4.
Set the grate retainer in place, in the notch in the
hearth.
Install the back panel. Center from side to side.
Install rear refractory retainer.
Side Refractory Retainer
Left Side Molded Brick Panel
Grate Retainer
Hearth Retainer
Figure 7.4
C. Install Side Molded Brick Panel
Remove screen rods.
Remove smoke shield
Install side panel by lifting up, setting on top flange of
hearth and slide towards back of unit until it meets up
with back panel.
Install refractory retainer
Install second side panel following the steps above.
Replace the smoke shield.
Install refractory retainer.
Back Refractory Retainer
Back Molded Brick Panel
Right Side Molded Brick Panel
Side Refractory Retainer
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Outdoor woodburning castlewood 42

Table of Contents